Online double-conversion and modular UPS systems for data centers, server rooms, hospitals and critical facilities. 1kVA to 800kVA, zero transfer time, IEC 62040-3 Class VFI-SS-111 standard.
- Online double-conversion — zero transfer time, continuous clean power output
- Modular UPS — scalable from 25kW modules, hot-swap redundancy
- Input power factor >0.99, output THD <3% for sensitive loads
- Manual bypass, EPO (Emergency Power Off) and SNMP card supported
- Battery room or rack-mounted configurations available
- IEC 62040-3 Class VFI-SS-111 certified — suitable for Tier III and IV facilities
MOQ / Project-based
Lead Time / 15-30 days
Supply / B2B / Wholesale
Origin / China
Product Overview
Uninterruptible power supply (UPS) systems provide continuous, conditioned power to critical loads during mains disturbances or outages. Online double-conversion UPS systems continuously regenerate the output from the inverter, providing zero transfer time and complete isolation from mains power quality problems.
RichingPower supplies online double-conversion UPS from 1kVA to 800kVA and modular UPS systems scalable from 25kW building blocks. Modular systems allow capacity to be added incrementally and provide N+1 redundancy without oversizing the initial installation.
All systems support external battery cabinets for extended backup runtime, SNMP network management cards for remote monitoring, and optional static bypass for maintenance access without interrupting the load.
Online vs Modular UPS
| Parameter | Online Double-Conversion | Modular UPS |
|---|---|---|
| Power Range | 1kVA – 800kVA | 25kW – 600kW (scalable) |
| Input Voltage | 1P 230V / 3P 380–415V AC | 3P 380–415V AC |
| Output Voltage | 1P 230V / 3P 380–415V AC | 3P 380–415V AC |
| Transfer Time | 0ms (online double-conversion) | 0ms (online double-conversion) |
| Input Power Factor | >0.99 (with PFC) | >0.99 |
| Output THD | <3% (linear load) | <2% (linear load) |
| Efficiency | Up to 96% (online mode) | Up to 97% (online mode) |
| Battery Type | VRLA (internal or external cabinet) | VRLA or Lithium (external cabinet) |
| Communication | SNMP card, RS232, dry contact | SNMP, Modbus, BMS integration |
| Protection | Overload, short circuit, over-temp, EPO | Overload, short circuit, over-temp, EPO |
| Applicable Standards | IEC 62040-1, IEC 62040-3 VFI-SS-111 | IEC 62040-1, IEC 62040-3 VFI-SS-111 |
UPS systems supplied by RichingPower are certified to the following standards. Please specify power rating, topology and applicable standard when submitting an enquiry.
UPS systems are used wherever continuous power availability is critical. System size and topology are selected based on load power, required backup runtime and facility tier classification.
Request a Quotation
Send us your load list or power requirement. Our team will recommend the right UPS topology, power rating and battery runtime for your project.
What to include in your enquiry:
We reply within 24 hours with a recommended configuration and indicative pricing.
Send Enquiry
Contact us via the enquiry form or WhatsApp for a faster response.
Go to Enquiry Form → WhatsApp Us