Power cables, control cables and network cables for data center electrical infrastructure. LSZH rated, high fire performance, suitable for raised floor, cable tray and plenum installation environments.

KEY FEATURES

MOQ / Project-based

Lead Time / 15-30 days

Supply / B2B / Wholesale

Origin / China

Product Overview

Data center cable procurement covers multiple cable categories within a single project: LV power cables from the main distribution board to UPS and PDU units, control cables for monitoring and switching systems, and structured network cables for IT infrastructure.

Data centers have specific requirements for fire performance, low smoke emission and halogen-free materials. RichingPower supplies all three cable categories with LSZH sheath, fire-resistant and fire-rated options suitable for raised floors, cable trays and plenum spaces.

We support consolidated project procurement covering all cable categories. Buyers can submit a full cable schedule for a single quotation covering power, control and network cables together.

Fire Performance Classifications

Flame Retardant (FR)
IEC 60332-1 / 60332-3 — does not propagate flame
Low Smoke (LS)
IEC 61034 — reduced smoke emission under fire
Halogen Free (LSZH)
IEC 60754-1 — no toxic halogen gases when burning
Fire Resistant (FP)
IEC 60331 / BS 6387 Cat C — 90 min circuit integrity at 950°C
Category Type Key Specification
Power CableLV Power Cable (LSZH)0.6/1kV, Cu, XLPE insulation, LSZH sheath, IEC 60502-1
Fire Resistant Cable0.6/1kV, Cu, mica tape, 90 min circuit integrity, IEC 60331 / BS 6387
Control CableShielded Control Cable0.6/1kV, Cu, overall foil + braid shield, LSZH sheath
Instrumentation Cable300/500V, individual + overall screen, LSZH, IEC 60227
Network CableCat6 UTP4-pair, 250MHz, solid copper, 1Gbps, TIA-568-C / ISO 11801
Cat6A SFTP4-pair, 500MHz, shielded, 10Gbps to 100m, PoE++ support
Patch CordsCat6 / Cat6A, 0.5m–10m, RJ45, boot color-coded

Data center cables supplied by RichingPower comply with the following standards. Please specify fire performance requirement and applicable standard when submitting an enquiry.

IEC 60502-1
LV power cables — international standard for B2B export projects.
IEC 60331 / BS 6387
Fire resistant cable — circuit integrity for 90 min at 750–950°C.
IEC 60754 / IEC 61034
LSZH and low smoke cable classification for confined spaces.
TIA-568-C (ANSI)
US standard for commercial building structured cabling systems.
ISO/IEC 11801
International standard for generic cabling for customer premises.
EN 50288 / EN 50267
European data and control cable standards.

Data center cable procurement typically covers multiple categories in a single project. The selection of fire performance rating and cable category depends on the installation zone and circuit criticality.

MDB to UPS Power Feeders
LSZH LV power cables from main distribution board to UPS units, bypass panels and static transfer switches.
UPS to PDU Distribution
Power distribution cables from UPS output to PDU units in raised floor or overhead cable management systems.
Emergency & Fire Circuits
Fire resistant cables for emergency lighting, fire alarm circuits and critical systems requiring circuit integrity under fire conditions.
Structured Network Cabling
Cat6 and Cat6A horizontal cabling runs from patch panels to server rack switch ports and ToR (top of rack) connections.
BMS & Monitoring Control
Shielded control cables for KVM systems, BMS sensors, cooling unit controls and environmental monitoring wiring.
Generator Room Cables
Power cables from generator to ATS (Automatic Transfer Switch) and from ATS to main distribution board.

Request a Quotation

Data center cable procurement typically covers multiple categories. Send us your full cable schedule for a consolidated quotation covering power, control and network cables.

What to include in your enquiry:

Project cable schedule — type, cores, cross-section, quantity per item
Fire performance requirement — FR, LSZH, FP / fire resistant
Network cable category and quantity — Cat6, Cat6A, patch cords
Installation method — raised floor, cable tray, conduit or plenum
Applicable standard — IEC, BS, TIA/ISO or other
Data center size (kW or number of racks) for quantity estimation
Destination country and delivery timeline

We support consolidated quotation across all cable categories and reply within 24 hours.

Send Enquiry

Contact us via the enquiry form or WhatsApp for a faster response.

Go to Enquiry Form → WhatsApp Us
✓ Reply within 24 hours
✓ Consolidated multi-category quotation
✓ Cable schedule accepted
✓ B2B / Wholesale supply
Scroll to Top