Switchgear
Low voltage and medium voltage switchgear panels for power distribution in industrial plants, commercial buildings and substations. ACB, VCB and MCB configurations, IEC 61439 / IEC 62271 standard.
- LV switchgear rated 400V up to 6300A busbar current capacity
- MV switchgear rated 6kV to 40.5kV for primary distribution
- ACB (Air Circuit Breaker) for LV main distribution panels
- VCB (Vacuum Circuit Breaker) for MV feeder and incomer circuits
- Protection relay options: overcurrent, earth fault and differential protection
- Type-tested to IEC 61439 (LV) and IEC 62271 (MV), custom layout on request
MOQ / Project-based
Lead Time / 15-30 days
Supply / B2B / Wholesale
Origin / China
Product Overview
Switchgear panels are used to control, protect and isolate electrical equipment in power distribution systems. They are the central component in main distribution rooms, substations and motor control centers, providing switching, protection and metering functions for incoming and outgoing circuits.
RichingPower supplies both low voltage switchgear (400V, up to 6300A) and medium voltage switchgear (6kV to 40.5kV). LV panels use ACB or MCB breakers for final distribution, while MV panels use VCB or SF6 breakers for primary distribution and substation applications.
Custom cubicle layout, busbar rating, breaker configuration and protection relay specification are available for project-specific requirements. Type-tested assemblies to IEC 61439 and IEC 62271 are standard.
Switchgear Types
400V ACB incomer + MCB outgoing, up to 6300A busbar
Starter, VFD and feeder modules in one assembly
6–24kV, compact switchgear for ring or radial networks
6–40.5kV VCB, draw-out type, for primary substation
| Parameter | LV Switchgear | MV Switchgear |
|---|---|---|
| Voltage Rating | Up to 1kV (400V typical) | 6kV – 40.5kV |
| Breaker Type | ACB, MCCB, MCB | VCB (Vacuum), SF6 |
| Busbar Rating | Up to 6300A | Up to 2500A |
| Short Circuit Rating | Up to 100kA (1s) | Up to 31.5kA (3s) |
| Protection Relay | Overcurrent, earth fault, under-voltage | Overcurrent, differential, distance |
| Enclosure | IP31 / IP41 / IP54 (indoor) | IP4X metal-clad (indoor) |
| Metering | CT / VT metering, energy meter optional | CT / VT metering, SCADA interface |
| Communication | Modbus RTU / Profibus (optional) | IEC 61850 / Modbus (optional) |
| Applicable Standards | IEC 61439-1 / IEC 61439-2 | IEC 62271-100 / IEC 62271-200 |
Switchgear supplied by RichingPower is type-tested to the following international standards. Please specify voltage level, breaker type and applicable standard when submitting an enquiry.
Switchgear is used at every level of power distribution — from utility substations down to final distribution in buildings and industrial plants. Selection depends on voltage level, fault current, and system protection requirements.
Request a Quotation
Send us your single-line diagram or equipment specification. Our team will review the requirement and provide a project-based quotation within 24 hours.
What to include in your enquiry:
A single-line diagram or equipment schedule helps us prepare the most accurate quotation. We reply within 24 hours.
Send Enquiry