Low voltage and medium voltage switchgear panels for power distribution in industrial plants, commercial buildings and substations. ACB, VCB and MCB configurations, IEC 61439 / IEC 62271 standard.

MOQ / Project-based

Lead Time / 15-30 days

Supply / B2B / Wholesale

Origin / China

Product Overview

Switchgear panels are used to control, protect and isolate electrical equipment in power distribution systems. They are the central component in main distribution rooms, substations and motor control centers, providing switching, protection and metering functions for incoming and outgoing circuits.

RichingPower supplies both low voltage switchgear (400V, up to 6300A) and medium voltage switchgear (6kV to 40.5kV). LV panels use ACB or MCB breakers for final distribution, while MV panels use VCB or SF6 breakers for primary distribution and substation applications.

Custom cubicle layout, busbar rating, breaker configuration and protection relay specification are available for project-specific requirements. Type-tested assemblies to IEC 61439 and IEC 62271 are standard.

Switchgear Types

LV Main Distribution Panel
400V ACB incomer + MCB outgoing, up to 6300A busbar
LV Motor Control Center (MCC)
Starter, VFD and feeder modules in one assembly
MV Ring Main Unit (RMU)
6–24kV, compact switchgear for ring or radial networks
MV Metal-Clad Switchgear
6–40.5kV VCB, draw-out type, for primary substation
ParameterLV SwitchgearMV Switchgear
Voltage RatingUp to 1kV (400V typical)6kV – 40.5kV
Breaker TypeACB, MCCB, MCBVCB (Vacuum), SF6
Busbar RatingUp to 6300AUp to 2500A
Short Circuit RatingUp to 100kA (1s)Up to 31.5kA (3s)
Protection RelayOvercurrent, earth fault, under-voltageOvercurrent, differential, distance
EnclosureIP31 / IP41 / IP54 (indoor)IP4X metal-clad (indoor)
MeteringCT / VT metering, energy meter optionalCT / VT metering, SCADA interface
CommunicationModbus RTU / Profibus (optional)IEC 61850 / Modbus (optional)
Applicable StandardsIEC 61439-1 / IEC 61439-2IEC 62271-100 / IEC 62271-200

Switchgear supplied by RichingPower is type-tested to the following international standards. Please specify voltage level, breaker type and applicable standard when submitting an enquiry.

IEC 61439-1 / -2
Low voltage switchgear and controlgear assemblies — type-tested and partially type-tested.
IEC 62271-100
High-voltage AC circuit breakers — VCB and SF6 breaker type testing.
IEC 62271-200
AC metal-enclosed switchgear and controlgear for rated voltages above 1kV.
GB/T 3906
China national standard for 3.6–40.5kV AC metal-enclosed switchgear.
GB/T 7251
China national standard for LV switchgear and controlgear assemblies.
IEC 61850
Communication standard for substation automation — available on MV panels on request.

Switchgear is used at every level of power distribution — from utility substations down to final distribution in buildings and industrial plants. Selection depends on voltage level, fault current, and system protection requirements.

Industrial Plants
Main distribution rooms, motor control centers and sub-distribution panels in factories and processing facilities.
Commercial Buildings
Main LV switchboards, riser distribution boards and tenant sub-metering panels in offices, hotels and hospitals.
Power Substations
MV switchgear for primary and secondary substations, ring main units and feeder pillar installations.
Data Centers
Main LV switchboards, UPS bypass panels and critical power distribution assemblies for Tier III and IV facilities.
Renewable Energy
MV collection switchgear for wind farms and solar plants, grid connection panels and energy storage integration.
Infrastructure Projects
Tunnel lighting panels, pumping station switchboards, airport and railway power distribution assemblies.

Request a Quotation

Send us your single-line diagram or equipment specification. Our team will review the requirement and provide a project-based quotation within 24 hours.

What to include in your enquiry:

Voltage level — LV (400V) or MV (6kV to 40.5kV)
Breaker type — ACB, MCCB, MCB (LV) or VCB, SF6 (MV)
Busbar rating and short circuit level (kA)
Number of incoming and outgoing feeders
Protection relay requirement
Applicable standard — IEC 61439, IEC 62271, GB or other
Destination country and project type

A single-line diagram or equipment schedule helps us prepare the most accurate quotation. We reply within 24 hours.

Send Enquiry

Contact us via the enquiry form or WhatsApp for a faster response.

Go to Enquiry Form → WhatsApp Us
✓ Reply within 24 hours
✓ Single-line diagram accepted
✓ Custom layout available
✓ B2B / Project supply
Scroll to Top