Home / Products / Electrical Cables / Medium Voltage Cable
Electrical Cables
Medium Voltage Cable
6kV to 35kV XLPE-insulated medium voltage cable for power grid feeders, industrial plant distribution and substation connections. Copper or aluminum conductor, IEC 60502-2 / GB / BS standard.
KEY FEATURES
- Voltage rating 3.6/6kV up to 26/35kV — suitable for MV power distribution
- Copper or aluminum conductor, Class 2 stranded to IEC 60228
- XLPE insulation with triple extrusion semi-conductive screens
- Copper tape or copper wire metallic screen options
- Armored variants: SWA and STA for direct burial or mechanical protection
- Custom drum lengths and export packing for project orders
MOQ / Project-based
Lead Time / 15-30 days
Supply / B2B / Wholesale
Origin / China
Product Overview
Medium voltage cables operate in the range of 3.6/6kV up to 26/35kV and are used to transmit electrical power between substations, from substations to industrial distribution boards, and in utility distribution networks.
RichingPower supplies MV cables with copper or aluminum conductors, XLPE insulation, and metallic screen options including copper tape, copper wire, and aluminum foil. Armored and non-armored types available.
Common type codes include YJV, YJLV, YJV22, YJLV22 (GB) and N2XSY, NA2XSY, N2XY (IEC/DIN). Custom lengths and export packing available for project procurement.
Cable Construction (inside out)
<div style=”overflow-x:auto;”>
<table style=”width:100%; border-collapse:collapse; font-size:14px;”>
<thead>
<tr>
<th style=”background:#111; color:#fff; padding:10px 14px; text-align:left; font-size:12px; font-weight:500; text-transform:uppercase; letter-spacing:0.06em; border:1px solid #111; width:38%;”>Parameter</th>
<th style=”background:#111; color:#fff; padding:10px 14px; text-align:left; font-size:12px; font-weight:500; text-transform:uppercase; letter-spacing:0.06em; border:1px solid #111;”>Specification</th>
</tr>
</thead>
<tbody>
<tr><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Voltage Rating</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV, 18/30kV, 26/35kV</td></tr>
<tr style=”background:#fafafa;”><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Conductor Material</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>Copper (Cu) or Aluminum (Al)</td></tr>
<tr><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Conductor Class</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>Class 2 stranded (IEC 60228)</td></tr>
<tr style=”background:#fafafa;”><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Cross-Section Range</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>25mm² – 630mm²</td></tr>
<tr><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Number of Cores</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>1 core (standard); 3-core available</td></tr>
<tr style=”background:#fafafa;”><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Insulation</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>XLPE — triple extrusion (conductor screen + insulation + insulation screen)</td></tr>
<tr><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Metallic Screen</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>Copper tape screen, copper wire screen, or aluminum foil + drain wire</td></tr>
<tr style=”background:#fafafa;”><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Inner Sheath</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>PVC or PE</td></tr>
<tr><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Armoring (optional)</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>SWA — steel wire armored; STA — steel tape armored</td></tr>
<tr style=”background:#fafafa;”><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Outer Sheath</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>Black PVC or LSZH</td></tr>
<tr><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Max Operating Temp</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>90°C (XLPE conductor)</td></tr>
<tr style=”background:#fafafa;”><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Common Type Codes</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>YJV, YJLV, YJV22, YJLV22 (GB); N2XSY, NA2XSY, N2XY, NA2XY (IEC/DIN)</td></tr>
<tr><td style=”padding:9px 14px; border:1px solid #e5e5e5; font-weight:500; color:#111;”>Applicable Standards</td><td style=”padding:9px 14px; border:1px solid #e5e5e5; color:#444;”>IEC 60502-2, GB/T 12706.2, BS 6622, HD 620</td></tr>
</tbody>
</table>
</div>
</div>
Medium voltage cables supplied by RichingPower are manufactured to the following standards. Please specify the required standard when submitting an enquiry.
<div style=”padding:32px 0;”>
<p style=”font-size:14px; color:#555; line-height:1.8; margin-bottom:24px; max-width:700px;”>
Medium voltage cables are used in power transmission and primary distribution projects where voltage levels exceed 1kV. Conductor size and screen type are selected based on fault current and installation method.
</p>
<div style=”display:grid; grid-template-columns:repeat(3,1fr); gap:16px;”>
<div style=”background:#f9f9f9; border-radius:4px; padding:16px 18px; border-left:3px solid #111;”>
<div style=”font-size:14px; font-weight:700; color:#111; margin-bottom:6px;”>Power Utility Networks</div>
<div style=”font-size:13px; color:#666; line-height:1.6;”>Primary and secondary feeders from 6kV to 35kV in utility distribution networks and grid infrastructure.</div>
</div>
<div style=”background:#f9f9f9; border-radius:4px; padding:16px 18px; border-left:3px solid #111;”>
<div style=”font-size:14px; font-weight:700; color:#111; margin-bottom:6px;”>Industrial Plant Feeders</div>
<div style=”font-size:13px; color:#666; line-height:1.6;”>Main incoming feeders from utility substation to factory main switchroom and MV distribution boards.</div>
</div>
<div style=”background:#f9f9f9; border-radius:4px; padding:16px 18px; border-left:3px solid #111;”>
<div style=”font-size:14px; font-weight:700; color:#111; margin-bottom:6px;”>Substation Connections</div>
<div style=”font-size:13px; color:#666; line-height:1.6;”>Between transformer LV terminals and MV switchgear panels in substations.</div>
</div>
<div style=”background:#f9f9f9; border-radius:4px; padding:16px 18px; border-left:3px solid #111;”>
<div style=”font-size:14px; font-weight:700; color:#111; margin-bottom:6px;”>Renewable Energy Projects</div>
<div style=”font-size:13px; color:#666; line-height:1.6;”>Wind farm and solar farm collector cables from turbines or inverters to substation.</div>
</div>
<div style=”background:#f9f9f9; border-radius:4px; padding:16px 18px; border-left:3px solid #111;”>
<div style=”font-size:14px; font-weight:700; color:#111; margin-bottom:6px;”>Underground Infrastructure</div>
<div style=”font-size:13px; color:#666; line-height:1.6;”>Duct or direct burial installations in urban infrastructure, roads and tunnel projects.</div>
</div>
<div style=”background:#f9f9f9; border-radius:4px; padding:16px 18px; border-left:3px solid #111;”>
<div style=”font-size:14px; font-weight:700; color:#111; margin-bottom:6px;”>Mining Sites</div>
<div style=”font-size:13px; color:#666; line-height:1.6;”>High-capacity power feeders to surface and underground mining equipment and distribution boards.</div>
</div>
</div>
</div>
Request a Quotation
To prepare an accurate quotation for medium voltage cables, please provide the following information.
What to include in your enquiry:
We will review your specification and reply with a project-based quotation within 24 hours.
Send Enquiry
Contact us directly via the enquiry form or WhatsApp for a faster response.
Go to Enquiry Form → WhatsApp Us